What do I need to record in my flight log?

What do I need to record in my flight log?

Please download a copy of the flight log template below, and upload a completed copy in .xlxs format with your data. 


FlightLog_Above_24a.xlsx


It must be completed for every zone, before and after every flight.

 

You must record:

  • Flight Zone name (e.g Z-03)
  • Flight start time. 
  • Flight number (Because one zone may require more than one flight, for example if you have technical issues or must wait for clouds to clear)
  • Irradiance at start of flight
  • Irradiance at End of flight
  • Temperature/Humidity (Information from a local weather app is acceptable if no local meter available)


    • Related Articles

    • Flight & Camera Parametres for a Thermographic Inspection

      This guide applies to the following sensor/drones mentioned in the Approved cameras & drones document. We divide each solar farm into 'Zones' for the purposed of flight planning and data transfer. These are the areas that you will map at a specified ...
    • Requirements when carrying out a thermographic inspection

      For each Inspection zone and Overview zone ✅ Thermal images from radiometric camera [IR] (.JPG) captured during "mapping" mission at the specified GSD ✅ Visual RGB images from wide camera [W] (.JPG) captured simultaneously with "mapping" mission For ...
    • What irradiance levels should I have during a thermographic inspection?

      The irradiance (nadir - 90° to the module) must exceed 600W/m2 at the time of data capture. Changing weather and cloud cover can mean that irradiance drops below this value. You must be aware of conditions at all times and, if necessary, pause or ...
    • Why has my thermographic inspection data been rejected?

      Above provides clear data guidelines to ensure the highest quality of analysis of each solar plant. Please see the issues below to provide context as to why the data could be rejected. Corrupt files When there is a considerable number of frames that ...
    • Site Photographs taken during a thermographic inspection

      Here are the requirements when it comes to Site photographs taken during a thermographic inspection: Capture at approximately 65m (or lower if flight restrictions dictate) Please capture 2-5 photos. Example site images: