Thermographic Report - Anomaly Groups
Health & Safety Impact
Items that may pose an immediate risk or liability to the plants health
and safety requirements.
- Visibly Damaged Modules
- Heated Substrings & Hot
Spots
- Elevated Hot Spot ΔTm Results
- String End Heating Pattern
(SEHP) which can be
attributable to negative earthing arrangement
Corrective Maintenance Performance Impact
Abnormalities occurring in such frequency or intensity to recommend for plant operators to take immediate corrective maintenance intervention to mitigate
observational risks.
- Unidentified Heated
Modules
- Unidentified Heated Strings
- Heated Sub & Multiple
Sub Strings
- Active Bypass
Diodes
- Heated DC Junction
Boxes
- Tracker Mis
Alignments
Preventative Maintenance Performance Impact
Abnormalities occurring in such frequency or intensity to recommend for plant operators to schedule observational risks into the preventative maintenance plan for additional inspection & testing.
- Unidentified Hot & Multiple Hot Spots
- Heated Modules secondary
to CM classifications.
- Overtightened Clamps
- Minor soiling or vegetation growth
- Surface Scratches
Low Effort / High Return Impact
Relates to items
when actioned result in measurable improvements to plant performance for the low effort typically required to rectify these items.
- Module Cleaning
- Landscaping
- Inter Row
Shade Impacts
- Interior Object Shade Impacts
- Exterior Plant Shade Impacts
Warranty Claim
Items displaying observational patterns typically associated with defects covered by industry standard manufacturer terms and conditions. Asset Owners should contact Above for support with dedicated remediation planning.
- Delamination
- Bus Bar Corrosion & Hot Spots
- Heated Sub Strings
- Heated Junction Boxes
- Heated Hypercells
Related Articles
Thermographic Report - Anomaly Types and Root Causes
Heated Module A module showing anomalous heating across the entirety of its surface. Heated modules can have an intrinsic root cause, or heating can occur secondary to an extrinsic root cause. A common extrinsic root cause is 'string heating', where ...
Thermographic Report - Survey Compare
Introduction The Survey Compare tool enables you to: Compare up to 3 inspections Have a high-level anomaly comparison Look at the evolution per module Get a detailed breakdown for each status The Survey Compare page has been designed to match the ...
Thermographic Report - Advanced Power Loss Estimation
The sophisticated Power Loss Estimation feature available on SolarGain enables you to: Better understand the impact anomalies found during thermal inspections have on the performance of your solar site Focus on solving issues on the lowest performing ...
Thermographic Report - Glossary
Acronym/Jargon Explanation AGL Above ground level (Altitude) ATL Above take-off level (Altitude) CAD Computer-aided design [document] Here, generally used to refer to schematic drawings of the layout of a solar plant. Delta-Tm (ΔTm) The measured ...
Visual Evidence Report