Digital Twin - Serial Number Management (Deletion) Tool

Digital Twin - Serial Number Management (Deletion) Tool

Overview

More sites are requiring serial number scanning to provide a unique identifier for each component. SolarGain Mobile (SGM) is used to scan these numbers. There are instances when serial numbers are scanned incorrectly. In the past, a special request was needed, taking hours/days for the Above Data Services team to delete a batch of serial numbers.

This tool has been created for those using SolarGain, so one or several serial numbers can be deleted immediately from the portal. This allows those who are scanning on site to rescan batches as required.

The changes are shown in the component history, so it is clear what the old serial number was and then a blank field, ready for rescanning.

Serial Number Management button

To find the serial numbers to delete, the Advanced Search button must be used to find the serial number. When the result(s) are found, the button "Serial Number Management" will be displayed.

Clicking on the "Serial Number Management" button will open up a window giving the following options for "Select delete mode":
  1. Individual module
  2. Entire table

Delete individual modules

When selecting individual modules, it will display the number of modules at the bottom (e.g. "Clicking confirm will remove serial numbers from 98 selected modules"


The user must type in the word delete to ensure the user is careful and doesn't click Confirm by mistake.


Delete entire table

When selecting entire tables, it will display the number of modules at the bottom (e.g. "Clicking confirm will remove serial numbers from 596 modules found on the same tables as the selected modules"


The user must type in the word delete to ensure the user is careful and doesn't click Confirm by mistake.


Confirmation message

Once the user clicks Confirm, they see a notification confirming the number of modules deleted.

Serial number history

Once a serial number is deleted, the activity will show up in the History drawer on the right, along with the other data related to that module.


The page will need to be refreshed in order to see this blank serial number field, showing the deletion is complete. This can be done by performing a new search, such as noting the table name and position. 
    • Related Articles

    • Digital Twin - History Tab

      Overview Our digital twin empowers users to compile all data collected during installation and commissioning, as well as manufacturer testing data, visual evidence and all task lists ever created. When a component is selected, it displays all ...
    • Digital Twin - General Display & Advanced Search

      General Display Overviews The Digital Twin page is a geospatial representation of the site which shows all the main electrical components of the site: transformers, inverters, combiner boxes, strings and modules. Advanced Search Functionality Add ...
    • Digital Twin - Filters

      Useful Examples 1. Locate thermal anomalies resolved. Anomalies appear in a given year, absent in subsequent analysis. 2. Locate new thermal anomalies Anomalies identified in a recent year, not observed in previous reports. 3. Locate persisting ...
    • Digital Twin - Search Criteria

      Introduction Once the search criteria are submitted, the system will show total quantity and a table with list of selected criteria including descriptions that have been on-boarded. Click to one of the list and the system will show all the relevant ...
    • Tasks - Task List Management

      Task List Overview Each Task List item when selected either from the Map or the List will expand the task’s information panel on the right. This panel contains all the original and running information for that item. Task List Item The image below ...