Useful Examples
1. Locate thermal anomalies resolved.
Anomalies
appear in a given year, absent in subsequent analysis.
2. Locate new thermal anomalies
Anomalies
identified in a recent year, not observed in previous reports.
3.
Locate persisting thermal anomalies
Anomalies detected in a specific year,
continuing through to subsequent years.
4. Locate modules with a thermal
anomaly and a visual damage
Modules with a thermal anomaly and visual evidence
attached.
5. Locate
modules with thermal defects associated to a singular batch
If
serial numbers from your modules have been scanned, you can potentially identify
batches and trends with a corresponding anomaly found from your thermal
reports.
6. Locate modules with thermal anomalies, belonging to different electrical
zones.
Anomalies
contained on a transformer level
Anomalies
contained on an inverter level
Anomalies
contained on a string level
7. Confirm
the Module on-site distribution
Modules
with a specific Nameplate Wp capacity “Nameplate Pmax"
Modules with a specific
Current Sorting value
8. Locate
modules with Factory EL Test
Modules
with an EL test on record
Any
string with a RISO test under 15 M ohm
10. Locate
modules from a specific delivery.
Modules originating from a
specific delivery container
Modules originating from a
specific delivery pallet
Related Articles
Digital Twin - History Tab
Overview Our digital twin empowers users to compile all data collected during installation and commissioning, as well as manufacturer testing data, visual evidence and all task lists ever created. When a component is selected, it displays all ...
Digital Twin - General Display & Advanced Search
General Display Overviews The Digital Twin page is a geospatial representation of the site which shows all the main electrical components of the site: transformers, inverters, combiner boxes, strings and modules. Advanced Search Functionality Add ...
Digital Twin - Search Criteria
Introduction Once the search criteria are submitted, the system will show total quantity and a table with list of selected criteria including descriptions that have been on-boarded. Click to one of the list and the system will show all the relevant ...
Digital Twin - Serial Number Management (Deletion) Tool
Overview More sites are requiring serial number scanning to provide a unique identifier for each component. SolarGain Mobile (SGM) is used to scan these numbers. There are instances when serial numbers are scanned incorrectly. In the past, a special ...
Tasks - Creating Task Lists
Task Lists are composed of various forms of specific site data available within SolarGain. The following section outlines how evidence from each available option can be added to Task lists for follow-up interactions. Create Task Lists Adding ...